|
Analyzers NewOpto-KY-90 system μmDepth&Height Measuring Scope Beam Profilers M2 Analyzer M2-Beam U3 M2-Beam-Si 350-1100nm M2-Beam-UV 190-1100nm M2-Beam-IR3 800-1800nm 3mm Dia M2-Beam-IR5 800-1800nm 5mm Dia M² HP/4KW BD for BA7-Si BeamOn U3 VIS-NIR 350-1600 BeamOn U3 UV-NIR 190-1600 BeamOn U3 HP BeamOn UV-NIR BeamOn VIS-NIR BeamOn IR-1550 BeamOn WSR UV-NIR BeamOn WSR VIS-NIR BeamOn HR BeamOn HR UV-VIS BeamOn HR AFW BeamOn HR-1550 uBeam uBeam HP BeamOn Longbow BeamOn LA Beam Analyzer Beam Analyzer HP BA3-Si BA7-Si BA3-UV BA7-UV BA3-IR3 BA7-IR3 BA3-IR3E BA7-IR3E BA3-IR5 BA7-IR5 BA7-IR10-USB(Diameter 10mm) BA3 for nearly TEMoo beam BA7 for not TEMoo beam BA7-Si/UV M2 Attachment BA7-IR M2 Attachment Beam Analyzer Touch LAM Beam Analyzer BeamOn X BeamOn X HP Alignmeter Sensing EAC-1012 Electronic Autocollimator EAC HR Electronic Autocollimator HR LAT-U3 Laser Analyzing Telescope EAC-1012-L Laser Analyzing Autocollimator AlignMeter ALIGNUSB-100-9x9mm ALIGNUSB-100-4x4mm ALIGNUSB-50-9x9mm ALIGNUSB-50-4x4mm ALIGN-LA AlignMeter Wide Aperture Knuckle Adaptor for AlignMeter AngleMeter AngleMeter LA 18mm input aperture CMOS USB2-Lens PSD4 USB-Lens PSD4 USB-HR-Lens PSD9 USB-Lens PSD4 Analog-Lens PSD4 Analog-HR-Lens PSD9 Analog-Lens Position Sensing SpotOn Compact SPOTCOM-L/N/Q/U SpotOn USB2.0 SPOTUSB-L/N/Q/U LaserOn BAT LaserOn PS SpotOn Mobile SPOTMOB-A SpotOn LA SPOTON-LA SpotOn CCD SPOTCCD-VIS SPOTCCD-UV SPOTCCD-IR-1310 SPOTCCD-IR-1550 SpotOn Analog SPOTANA-4-L/H SPOTANA-9-L/H SpotOn Analog USB SPOTANA-4-USB-Low/High SPOTANA-4S-USB-Low/High SPOTANA-9-USB-Low/High SPOTANA-9S-USB-Low/High Wavemeter FZW600 400-1100nm(all wavelength range) Accuracy 600MHz MWM 400-1100nm(calibrated at one wavelength) Accuracy ±1GHz/±1pm, eg. calibrated at 780nm±12nm MWM-633 623.5-641.3nm Accuracy 1pm SHR190-1100nm Accuracy ±3pm SHR-IR600-1800nm Accuracy ±20pm Power meter Si detector, 380-1100nm, 100pW-10mW, 11mm Si-UV detector, 200-1100nm, 100pW-1mW, 11mm InGaAs detector, 800-1650nm, 100pW-10mW, 3mm Spectrometer 200-1100nm, 0.16-1.6nm, 2068×70 190-1100nm, 1.0nm, 3648 200-400nm, 0.9-1.2nm, 512 200-2560nm, 0.06-10nm, 2068×512 IRviewer ABRIS M 350-1300nm、350-1700nm、350-2000nm SM-3R 350-1700nm、350-2000nm 84499 85100 85268 89400 85300 85700 85706 85050A 85051A InfraCal 2 ATR-SP / InfraCal 2 TRANS-SP InfraCal 2 ATR-SP InfraCal HATR-T2 InfraCal 2 TRANS-SP InfraCal CVH TOG/TPH FOG Oil min range 0.3ppm(ATR-SP) 0.1ppm(TRANS-SP) Soil min range 3ppm(ATR-SP) 1ppm(TRANS-SP) Vertrel MCA(ATR-SP) S-316 Freon-113(TRANS-SP) EPA 1664 ISO 9377-2 ASTM D7066 EPA 413.2 EPA 418.1 Biodiesel in Diesel Analyzer Ethanol in Gasoline Analyzer Oil in Water and Soil Analyzer InfraCal 2 Soot Meter range 0-15% ±0.2% time<30s ASTM D7686 and FTIR methods SPF(SPF-290AS) wavelength range 290-400nm accuracy 0.2%(0.58-0.80nm) repeatability 0.25nm linewidth 1.66nm absorbance 0-3.2A SP range 1-100+ time ≤24s scan step: 1nm,2nm,5nm light source 125W cw xenon lamp detector PMT X-Y electric translation stage Laser eyewear ARG(OD7+ VTL48%) 180-532nm(266nm 355nm 405nm 488nm 532nm) BGR(OD≥1 VLT29%) 440-640nm(450nm 532nm 640nm) ZS2(OD6+ VLT19% 532nm 561nm KRR(OD5+ VTL18%) 606-694nm(630nm 633nm 650nm 690nm) YG2(OD≥5 VLT25%) 720-1090nm(730nm 750nm 785nm 808nm 1064nm) YG3(OD≥5 VLT59%) 840-1090nm(980nm 1030nm 1064nm 1070nm) FG1(OD≥3+ VLT75%) 850-10600nm(2940nm) EC2(OD7+ VTL93%) 9000-11000um(9.3um 10.6um) Agile RF synthesizer ARF021 Agile RF synthesizer, 2 channels, 100mW per channel ARF421 AOM driver, agile RF synth, 2 channels, 4 watts per channel XRF021 As for ARF021, high-speed FPGA XRF421 As for ARF421, high-speed FPGA QRF041 4 channels, 100mW per channel QRF241 4 channels, 2 watts per channel End |
Phone:(+86)571-85152711 Cell:(+86)18857115252 Email:Sales@NewOpto.com Copyright©2011-2025 NewOpto Technology Corporation (Hangzhou) Limited 杭州新势力光电技术有限公司 / 备案号浙ICP备11028292号-1 2011MAY20-2023SEP8 The Best or Nothing |