半导体激光器
Product (现货供应)

SPF测试仪SPF-290AS



SPF-290AS Turnkey Automated Analyzer
SPF-290AS Sunscreen Protection Factor Analyzer
SPF-290AS防晒系数分析仪


Meets ISO24443 Requirements to In-Vitro SPF Analysis including
Liquids
Textiles
Lotions
Creams
Sprays
Gels
Powders
Emulsions


an integrated turnkey system, the following parts also including
a Validation Kit
a 50x50mm PMMA plate holder
a sample set of three 5u roughness PMMA plates
a box of 25 syringes
additional boxes of two hundred PMMA plates in either 2 or 5 roughness


The SPF-290AS Validation Kit including
Storage case
10 syringes with tips, 1ml, disposable
PMMA plates, 50x50mm, 5u roughness, sample set of 3
Samples holder for 50x50mm PMMA plates
Calibration Filter Plate assembly
1 oz jar of Homosalate Standard
1 oz jar of COLIPA Standard
Factory Calibration Data


Options including
3M Transpre tape
Transpore tape holders


Worldwide Customers including
Avon, BASF, Clairol, Elizabeth Arden, Estee Lauder, Good Housekeeping, ISP, Johnson & Johnson, Lever Bros, L’Oreal, Mary Kay, Merck, Revlon, Rohm & Haas, Proctor & Gamble, Unilever, Andrew Jergens, Helene Curtis, Whitehall Robins, Bayer, S.C. Johnson, Bristol-Myers Squibb, Tanning Research, Pfizer, Boots the Chemist UK Ltd., Amway

联合利华、上海强生、上海家化、上海雅芳、伽蓝集团、曼秀雷敦、华测检测
上海市疾病预防控制中心、四川省疾病预防控制中心、义乌出入境检验检疫局、国家日用小商品质量监督检验中心
复旦大学、北京工商大学、武汉工程大学


SPF-290AS Turnkey Automated Analyzer

Wavelength Range

290 - 400nm (Range Specified by International Methods)

Wavelength Accuracy

0.2% (0.58-0.80 nm)

Reproducibility

0.25 nm

Spectral Bandwidth

1.66 nm

Absorbance

0 - 3.2 A (Dual Doped PMMA Method)

SPF Range

1 - 50+

Scan Time

< 24 Seconds

Step Interval

1 nm, 2 nm, 5 nm, User Selectable

Lamp

Power Stabilized Xenon CW 125W (Operated at 75W)

Detector

High Sensitivity Multialkali side-on PMT

Sample Positioning

Automated X-Y Stage

Power Options

110VAC 60Hz, 220VAC 50Hz

Current Methods including

COLIPA/ISO in-vitro method for UVA-PF/SPF ratio (for EU labeling)

Critical Wavelength (for EU Labeling) Boots Star Rating (for EU Labeling)

FDA Critical Wavelength (for US Labeling) Monograph FDA 21 CFRAATCC-183 Fabric Test Method

AS NZS 4399 Sun Protective Clothing Standard, SPF ValuesAustralian TNUV Standards

UVA/UVBUVA Protective Factor CalculationsErythemal Protection Factor calculations

ISO: 24443 Untreated substrate measurement and data storage





 