电话: 400-007-1064
邮箱:
Sales@NewOpto.com
半导体激光器
产品销售

Wilks油脂分析仪



新势力光电供应Wilks油脂分析仪,是一种简便而准确的红外在线分析方法,用于检测:水中的油(TOG, Total Oil and Grease)、土壤中的石油烃(TPH, Total Petroleum Hydrocarbons)、废水中的油脂(FOG, Fats, Oil and Grease)。该系列TOG/TPH油脂分析仪FOG/TOG油脂分析仪特点:检测速度快(10-15分钟)、检测范围宽(0.1ppm-5000ppm 脂肪烃和芳香烃)、结构紧凑(165×165×127mm³, 2.2kg)、检测标准严格(ASTM D7066和EPA 166),目前在全球范围超过3000套的使用量,已经成为油脂检测和监控的行业标准。依据检测灵敏度和提取溶剂的区别,如下型号可供选择:InfraCal Model HATR-T2、InfraCal Model CVH、InfraCal Model CH、InfraCal 2 Model ATR-SP、InfraCal 2 Model TRANS-SP,其中
InfraCal 2 Model ATR-SP、InfraCal 2 Model TRANS-SP两款最新产品,带液晶触摸显示屏,如下图。



Model

InfraCal HATR-T2

InfraCal CVH

InfraCal 2 ATR-SP

InfraCal 2 TRANS-SP

Min detection Water

8 ppm

2 ppm

0.3 ppm

0.1 ppm

Min detection Soil

40 ppm

10 ppm

3 ppm

1 ppm

Solvent

Hexane, Pentane, Cyclohexane, Vertrel MCA

Perchloroethylene, S-316, Freon-113

Hexane, Pentane, Cyclohexane, Vertrel MCA

Perchloroethylene, S-316, Freon-113

Components measured

Hydrocarbons with boiling point higher than solvent

All hydrocarbons

Hydrocarbons with boiling point higher than solvent

All hydrocarbons

Method complies

NA

ASTM D7066, EPA 413.2 EPA 418.1

NA

ASTM D7066, EPA 413.2 EPA 418.1

Method compares

EPA 1664, ISO 9377-2

EPA 1664, ISO 9377-2

EPA 1664, ISO 9377-2

EPA 1664, ISO 9377-2

Volatile componets

Loses

Includes

Loses

Includes

Data acquisition

Printer from Wilks

Printer from Wilks

Internal data storage & export

Internal data storage & export

Calibrations

Single

Single

Multiple

Multiple

Display

4 character LED

4 character LED

Touch screen

Touch screen

Password protection

No

No

Yes

Yes

Battery pack

External

External

Internal

Internal

Others

Solvents lighter than water, sample collected form container top

Solvents heavier than water, requires separatory funnel or septa cap vial

Solvents lighter than water, sample collected form container top

Solvents heavier than water, requires separatory funnel or septa cap vial


Model

P/N

Description

Min Detection 8 ppm

405-1009

Includes 100 mrcroliter sypringe, Un-calibrated

InfraCal Model HATR-T2

405-1009-44

Factory calibrated using 403-1044

403-1044

TOG/TPH calibration standard set

405-1009-72

Factory calibrated using 403-1072

403-1072

FOG/TOG calibration standard set

403-1067

InfraLog serial printer

403-0013

Carrying case

403-0003

External 12V battery pack

403-0002

12V automotive power adapter cable

403-0005

Dust cover

403-1011

Field sampling kit

Min Detection 2 ppm

405-0003/12

Includes set of 4-10mm cuvettes, Un-calibrated

InfraCal Model CVH

405-0003/12-41

Factory calibrated using 403-1041

403-1041

S-316 TOG/TPH calibration standard set

405-0003/12-40

Factory calibrated using 403-1040

403-1040

S-316 FOG/TOG calibration standard set

405-0003/12-78
405-0003/12-64

Factory calibrated using 403-1064

403-1064

Tetrachloroethylene (Perchloroethylene) TOG/TPH calibration standard set

403-0012

Set of 4-10mm quartz cuvette cells

403-1067

InfraLog serial printer

403-0013

Carrying case

403-0003

External 12V battery pack

403-0002

12V automotive power adapter cable

403-0005

Dust cover

403-1063

Field sampling kit

Min Detection 0.3 ppm

405-2034

Includes set of 4-10mm cuvettes, Un-calibrated

InfraCal 2 Model ATR-SP

405-2034-81

Factory calibrated using 403-1081

403-1081

Hexane TOG/TPH calibration standard set (Low range)

405-2034-44

Factory calibrated using 403-1044

403-1044

Hexane TOG/TPH calibration standard set (High range)

405-2034-8144

Factory calibrated using 403-1081 and 403-1044

405-2034-72

Factory calibrated using 403-1072

403-1072

Hexane FOG/TOG calibration standard set

403-0013

Carrying case

403-1011

Field sampling kit

Min Detection 0.1 ppm

405-2035

Includes set of 4-10mm cuvettes, Un-calibrated

InfraCal 2 Model TRANS-SP

405-2035-80

Factory calibrated using 403-1080

403-1080

S-316 TOG/TPH calibration standard set (Low range)

405-2035-41

Factory calibrated using 403-1041

403-1041

S-316 TOG/TPH calibration standard set (High range)

405-2035-8041

Factory calibrated using 403-1080 and 403-1041

405-2035-40

Factory calibrated using 403-1040

403-1040

S-316 FOG/TOG calibration standard set

405-2035-79

Factory calibrated using 403-1079

403-1079

Tetrachloroethylene (Perchloroethylene) TOG/TPH calibration standard set (Low range)

405-2035-78

Factory calibrated using 403-1078

403-1078

Tetrachloroethylene (Perchloroethylene) TOG/TPH calibration standard set (High range)

405-2035-7978

Factory calibrated using 403-1079 and 403-1078

403-0012

Set of 4-10mm quartz cuvette cells

403-0013

Carrying case

403-1063

Field sampling kit

403-1083

Field sampling kit for sub-ppm


www.NewOpto.com
电话:0571-85152711  传真:0571-85152722  邮箱:Sales@NewOpto.com